Showroom at 24th Floor, Block A, Song Da Building, Pham Hung Street, Hanoi

ICOUNT OIL SAMPLER (IOS)

Size : W299 x D248 x H195/400 mm
Materials :
In Stock: Còn hàng
Price: Contact
Contact Now
The Price above does not include VAT (10%)

Online Ordering Support

Hotline 84 24 3205 3999
  • Description
  • Spectifications
  • Shipping
  • Warranty policy

Accurate Condition Monitoring made Quick, Simple and Cost Effective 

 

The icountOS (IOS) is an innovative solution to the challenge of measuring the quality of hydraulic oils and hydrocarbon fuels in many different applications: from renewable energy, marine and offshore, to manufacturing, mobile, agriculture, military and aerospace. 

 

How It Works

The IOS quality condition monitor for hydraulic oils and hydrocarbon fuels uses advanced technology to produce extremely repeatable results.
At the heart of the system is a sophisticated laser detector, using a light obscuration flow cell, providing continuous measurement of fluid flow passing through a sample tube.

Measurements are taken every second as standard, although measurement intervals and test period can be defined by the user, with results being reported immediately and updated in real time. Data is displayed on a built-in OLED digital display and can also be stored for subsequent upload via the embedded icount’s web page interface connecting through an RJ45 cable.

 

 

 

Features

Proven laser detecton technology

High onboard test data storage capacity

Quick connection
Tough storm case
Fast contamination detection
Complies with the latest standards
Long life remote operation
Fluid and pressure control
Pressure reducing valve (prv)

 

Feature Specification
Product start-up time 10 seconds minimum
Measurement period Default 30 seconds run time; 15 seconds data logging time
Reporting interval Onboard data storage every second. Output via RJ45 connection
Principle of operation Laser diode optical detection of actual particulates
International codes range Up to ISO 22 (+/- 1 ISO code) NAS 0-12
Calibration Calibration by recognized online methods confrmed by the relevant ISO procedures.
MTD – via a certifed primary ISO 11171 automatic particle detector using ISO 11943
principles. Particle distribution reporting to ISO 4406:1999
Recalibration and Servicing Recommended every 12 months
Working pressure 35-5000 psi (2.5–350 bar) Pressures above 35 psi require the use of a Parker
Pressure Reducing Valve (PRV) – ACC6NN027
Working viscosity 1-300 cSt
Flow range through IOS 40–140ml/minute; controlled at 60ml/min by IOS’s internal pump
Fluid connection interface INLET: .236 inch (6mm) push-ft. DRAIN: .157 inch (4mm) push-ft
Ambient storage temperature for unit –40ºC to +80ºC; –40ºF to +176ºF
Operating temperature for unit –30ºC to +80ºC; –22ºF to +176ºF
Operating humidity range 5%RH to 100%RH
Fluid operating temperature (Oil) +5ºC to +80ºC; +41ºF to +176ºF
Fluid operating temperature (Fuel) –20ºC to +70ºC; –4ºF to +158ºF
Moisture sensor Linear scale within the range 5%RH to 100%RH
Computer compatibility IP68-rated RJ45 connection that may be connected to a laptop computer’s RJ45
LAN port using the 2m cable supplied
Power requirement Regulated power supply supplied with the unit
Certifcation IP54 rating (unit open)
IP67 rating (unit closed)
EC Declaration of Conformity
Machinery Directive
EMC EN61000-6-3:2001
EMC EN61000-6-2:2001
EMC EN61010-1:2001
CE Certifed

 

Freeship